PromptShop

Single Cell Rna Qc

This skill automates the quality control (QC) workflow for single-cell RNA-seq data, following scverse best practices. It helps users filter low-quality cell...

Install

npx promptshop add single-cell-rna-qc

Details

What This Skill Does

This skill automates the quality control (QC) workflow for single-cell RNA-seq data, following scverse best practices. It helps users filter low-quality cells, assess data quality, and generate QC visualizations. It is designed for researchers who need to perform standard QC on their single-cell data.

When to Use

  • Perform quality control on single-cell RNA-seq data.
  • Filter low-quality cells based on various metrics.
  • Assess data quality using visualizations and metrics.
  • Follow scverse/scanpy best practices for QC.
  • Detect outliers using MAD-based filtering.
  • Batch process QC for multiple datasets.

Key Features

  • Supports .h5ad and 10X Genomics .h5 input formats.
  • Offers a complete QC pipeline for standard workflows.
  • Provides a convenience script for automated QC analysis.
  • Allows customization of filtering thresholds and gene patterns.
  • Generates QC reports with visualizations and metrics.
  • Implements MAD-based filtering for outlier detection.

Manual Installation

Manual installation View Full Skill Content The complete markdown content that gets installedSingle-Cell RNA-seq Quality Control

Automated QC workflow for single-cell RNA-seq data following scverse best practices.

When to Use This Skill

Use when users: Request quality control or QC on single-cell RNA-seq data Want to filter low-quality cells or assess data quality Need QC visualizations or metrics Ask to follow scverse/scanpy best practices Request MAD-based filtering or outlier detection

Supported input formats: .h5ad files (Ann Data format from scanpy/Python workflows) .h5 files (10X Genomics Cell Ranger output)

Default recommendation: Use Approach 1 (complete pipeline) unless the user has specific custom requirements or explicitly requests non-standard filtering logic.

Approach 1: Complete QC Pipeline (Recommended for Standard Workflows)

For standard QC following scverse best practices, use the convenience script scripts/qc_analysis.py:

python3 scripts/qc_analysis.py input.h5ad or for 10X Genomics .h5 files: python3 scripts/qc_analysis.py raw_feature_bc_matrix.h5

The script automatically detects the file format and loads it appropriately.

When to use this approach: Standard QC workflow with adjustable thresholds (all cells filtered the same way) Batch processing multiple datasets Quick exploratory analysis User wants the "just works" solution

Requirements: anndata, scanpy, scipy, matplotlib, seaborn, numpy

Parameters:

Customize filtering thresholds and gene patterns using command-line parameters: --output-dir - Output directory --mad-counts, --mad-genes, --mad-mt - MAD thresholds for counts/genes/MT% --mt-threshold - Hard mitochondrial % cutoff --min-cells - Gene filtering threshold --mt-pattern, --ribo-pattern, --hb-pattern - Gene name patterns for different species

Use --help to see current default values.

Outputs:

All files are saved to _qc_results/ directory by default (or to the directory specified by --output-dir): qc_metrics_before_filtering.png - Pre-filtering visualizations qc_filtering_thresholds.png - MAD-based threshold overlays qc_metrics_after_filtering.png - Post-filtering quality metrics _filtered.h5ad - Clean, filtered dataset ready for downstream analysis _with_qc.h5ad - Original data with QC annotations preserved

If copying outputs for user access, copy individual files (not the entire directory) so users can preview them directly.

Workflow Steps

The script performs the following steps:

Calculate QC metrics - Count depth, gene detection, mitochondrial/ribosomal/hemoglobin content Apply MAD-based filtering - Permissive outlier detection using MAD thresholds for counts/genes/MT% Filter genes - Remove genes detected in few cells Generate visualizations - Comprehensive before/after plots with threshold overlays

Approach 2: Modular Building Blocks (For Custom Workflows)

For custom analysis workflows or non-standard requirements, use the modular utility functions from scripts/qc_core.py and scripts/qc_plotting.py:

Run from scripts/ directory, or add scripts/ to sys.path if needed

import anndata as ad from qc_core import calculate_qc_metrics, detect_outliers_mad, filter_cells from qc_plotting import plot_qc_distributions # Only if visualization needed

adata = ad.read_h5ad ('input.h5ad') calculate_qc_metrics (adata, inplace=True) ... custom analysis logic here

When to use this approach: Different workflow needed (skip steps, change order, apply different thresholds to subsets) Conditional logic (e.g., filter neurons differently than other cells) Partial execution (only metrics/visualization, no filtering) Integration with other analysis steps in a larger pipeline Custom filtering criteria beyond what command-line params support

Available utility functions:

From qc_core.py (core QC operations): calculate_qc_metrics (adata, mt_pattern, ribo_pattern, hb_pattern, inplace=True) - Calculate QC metrics and annotate adata detect_outliers_mad (adata, metric, n_mads, verbose=True) - MAD-based outlier detection, returns boolean mask apply_hard_threshold (adata, metric, threshold, operator='>', verbose=True) - Apply hard cutoffs, returns boolean mask filter_cells (adata, mask, inplace=False) - Apply boolean mask to filter cells filter_genes (adata, min_cells=20, min_counts=None, inplace=True) - Filter genes by detection print_qc_summary (adata, label='') - Print summary statistics

From qc_plotting.py (visualization): plot_qc_distributions (adata, output_path, title) - Generate comprehensive QC plots plot_filtering_thresholds (adata, outlier_masks, thresholds, output_path) - Visualize filtering thresholds plot_qc_after_filtering (adata, output_path) - Generate post-filtering plots

Example custom workflows:

Example 1: Only calculate metrics and visualize, don't filter yet adata = ad.read_h5ad ('input.h5ad') calculate_qc_metrics (adata, inplace=True) plot_qc_distributions (adata, 'qc_before.png', title='Initial QC') print_qc_summary (adata, label='Before filtering')

Example 2: Apply only MT% filtering, keep other metrics permissive adata = ad.read_h5ad ('input.h5ad') calculate_qc_metrics (adata, inplace=True)

Only filter high MT% cells high_mt = apply_hard_threshold (adata, 'pct_counts_mt', 10, operator='>') adata_filtered = filter_cells (adata, ~high_mt) adata_filtered.write ('filtered.h5ad')

Example 3: Different thresholds for different subsets adata = ad.read_h5ad ('input.h5ad') calculate_qc_metrics (adata, inplace=True)

Apply type-specific QC (assumes cell_type metadata exists) neurons = adata.obs['cell_type'] == 'neuron' other_cells = ~neurons

Neurons tolerate higher MT%, other cells use stricter threshold neuron_qc = apply_hard_threshold (adata[neurons], 'pct_counts_mt', 15, operator='>') other_qc = apply_hard_threshold (adata[other_cells], 'pct_counts_mt', 8, operator='>')

Best Practices

Be permissive with filtering - Default thresholds intentionally retain most cells to avoid losing rare populations Inspect visualizations - Always review before/after plots to ensure filtering makes biological sense Consider dataset-specific factors - Some tissues naturally have higher mitochondrial content (e.g., neurons, cardiomyocytes) Check gene annotations - Mitochondrial gene prefixes vary by species (mt- for mouse, MT- for human) Iterate if needed - QC parameters may need adjustment based on the specific experiment or tissue type

Reference Materials

For detailed QC methodology, parameter rationale, and troubleshooting guidance, see references/scverse_qc_guidelines.md. This reference provides: Detailed explanations of each QC metric and why it matters Rationale for MAD-based thresholds and why they're better than fixed cutoffs Guidelines for interpreting QC visualizations (histograms, violin plots, scatter plots) Species-specific considerations for gene annotations When and how to adjust filtering parameters Advanced QC considerations (ambient RNA correction, doublet detection)

Load this reference when users need deeper understanding of the